Triax 023269 Datasheet Page 137

  • Download
  • Add to my manuals
  • Print
  • Page
    / 260
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 136
137
Technical data
TMS taps and splitter
Triax TMS IF taps and splitters
Expand the TMS 5x series into a cascadable system
Using TMS 55 taps makes it possible to construct large cascadable systems.
Different tap-values allow fine-tuning of available signal levels.
By using splitters you can balance your distribution
system the best possible way.
TYPE
Part No.
TMS 55-12
tap
300313
TMS 55-15
tap
300333
TMS 55-20
tap
300343
TMS 55-24
tap
300353
TMS 55-6S
splitter
300363
TMS 510
splitter
300319
Number of inputs 4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
Number of outputs 4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
8 SAT
2 TER
8 SAT
2 TER
Number of taps 4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
4 SAT
1 TER
Connectors
F-con
female female
female
female female
female
Frequency range SAT MHz 950-2150 950-2150 950-2150 950-2150 950-2150 950-2150
Frequency range MHz 47-862 47-862 47-862 47-862 47-862
Through loss SAT dB 1.2 ± 1 1.2 ± 1 1.2 ± 1 1.2 ± 1 1.2 ± 1 4 ± 1
Through loss TER dB 2.5 ± 1.5 2.5 ± 1.5 2.5 ± 1.5 2.5 ± 1.5 6 ± 1
Tap loss SAT dB 12.5 15 20 24 6.0
Tap loss TER dB 12.5 15 20 24
Isolation trunkline dB > 30 > 30 > 30 > 30 > 30 > 30
Isolation SAT - TER dB
Isolation TER - SAT dB
Power consumption VA
Temperature range
o
C
0...+55 0...+55 0...+55 0...+55 0...+55 0...+55
Dimensions - height
- width
- depth
mm
mm
mm
145
119
42
145
119
42
145
119
42
145
119
42
145
119
42
145
119
42
TMS 55-xx tap
TMS 510 splitter
Page view 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 259 260